Description and Application
Low-emission, well-flowing cementitious levelling compound for leveling substrates prior to laying textile and elastic floor coverings. Suitable for indoor use and easily pumpable.
Applicable for:
- Levelling absorbent subfloors for laying carpet, PVC, CV, PVC strips or tiles, linoleum
- Normal loads in residential and project environments
- Hot water floor heating and caster load in accordance with DIN EN 12529 from 1 mm layer thickness
Suitable on substrates such as:
- Cement screeds, concrete, terrazzo, new cast asphalt floors (up to 5 mm)
- Magnesite and wood stripped floors, dry building systems
- Renovation floors with well bonded, waterproof adhesive or leveling residues
- Existing ceramic and natural stone floors, terrazzo
For heavy loads (hospitals, warehouses, industry) use UZIN NC 170.
For anhydrite-bound substrates: UZIN NC 110 or UZIN NC 112 Turbo. For wooden substrates and cast asphalt: UZIN NC 115.
Features / Product Benefits
- Layer thickness from 1 to 10 mm
- Excellent flow and pumpability
- Good sandability
- High absorbency
- Chromate arm
- EMICODE EC 1 R PLUS – very low emission
Recommended Primer
- Cement screed, concrete (with adhesive residues): UZIN PE 360 PLUS or UZIN PE 375
- Moist cement-bound substrates: UZIN PE 400 or UZIN PE 460
- Wood, chipboard: UZIN PE 630
- Magnesite, terrazzo, granito, ceramic, dense concrete floors, plastic: UZIN PE 280
- Poured asphalt: UZIN PE 280
Processing
- Add about 5 liters of cold, clean water to a mixing vessel and gradually mix the powder into a homogeneous, lump-free mass. Do not mix too thinly.
- Pour the mixture onto the substrate and spread with leveling trowel or leveling rake. Immediately after application, prickle with a prickle roller for optimum results. Apply in one layer if possible.
- Applicable after approx. 24 hours per 3 mm layer thickness. Sanding with grain 40-60 improves surface and absorbency.
Consumption
Approximately 1.5 kg/m² per mm layer thickness. At 10 mm layer thickness, consumption is approximately 15 kg/m².
Prevent Cracking
Avoid cracks by not applying the leveling layer tightly to the wall. Use an edge strip to accommodate expansion. Always use a suitable primer under the leveling layer.
More Information
View comprehensive product, application and safety information under the “Product Appendices” tab on the UZIN NC 150 product page.
Reviews